GEODETIC ASSESSMENT OF STRUCTURAL DEFLECTIONS IN A HIGH-RISE BUILDING UNDERGOING CONTROLLED DEMOLITION USING TOTAL STATION MEASUREMENTS

Article scientifique 2026 Anglais

Résumé

Geodetic monitoring via Total Station (TS) surveying provides a model-independent framework for characterizing quasi-static structural displacement in high-rise reinforced concrete buildings undergoing controlled deconstruction; hence, augmenting vibration-based methods that are constrained in addressing gradually accumulating deformation. This paper presents a systematic, six-campaign TS displacement analysis conducted over 47 days on a 14-storey RC study building undergoing NDT-informed controlled deconstruction in Lagos, Nigeria. Taking multiple floor-level measurements on bother both left and right sides with 24 prism targets on Floors 2–13. The baseline displacement profile for the right face followed a second-order polynomial distribution that depended on height with R² = 0.933. The highest observed displacement was 15.53 mm at Floor 2. The active penthouse deconstruction caused a statistically significant increase in displacement with cumulative right-face displacements reaching 31.08 mm representing 102% increase over baseline. The average growth rates were 0.46 mm/day on the right face and 0.29 mm/day on the left face, with the highest rate being 0.74 mm/day on Floor 2. The global tilt at Floor 2 went up from 222.4 to 445.2 millidegrees and remained constant after week 4. The maximum displacement was 31.1% of the 100 mm safety threshold, which was the highest. The validated geodetic dataset can be used as the principal reference for cross-validation with associated vibration sensor and differential GNSS measurements in further studies.

Citer ce document

Nwodo, G. O., & Dumosu, J. O. (2026). GEODETIC ASSESSMENT OF STRUCTURAL DEFLECTIONS IN A HIGH-RISE BUILDING UNDERGOING CONTROLLED DEMOLITION USING TOTAL STATION MEASUREMENTS. https://doi.org/10.5281/zenodo.21479491

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 02/10/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 1

Téléchargements : 0