{# Audit 04/10/2026 : « autre » n'est pas un code de langue ; SPHAERO n'est pas l'éditeur des documents qu'elle héberge ou référence. #} {# citation_pdf_url doit mener à un PDF : un lien vers une page DOI est pénalisé par Google Scholar (avant : tout lien externe). #}
Accès ouvert · CC BY

Patient satisfaction with conventional versus fully digital obturators fabricated with 3D printing: a randomized crossover trial

Article scientifique 2025 Anglais

Résumé

BACKGROUND: Evidence concerning the performance of entirely 3D printed digital obturators is insufficient. This prospective randomized, single-blind crossover study aimed to evaluate patient satisfaction with conventional obturators and 3D printed obturators. METHODS: Ten patients aged between 45 and 65 years with unilateral hemi-maxillectomy due to oncological surgeries were enrolled in a crossover design. Initial treatment involved a conventional obturator with a heat-cured acrylic base and a cast metal framework GI. Following a two-week washout, patients received a fully digitally designed and fabricated obturator incorporating 3D printed materials GII. Satisfaction was assessed using the validated Obturator Functioning Scale (OFS), and statistical analysis was conducted using the Mann-Whitney U test. RESULTS: The median of OFS scores of the two groups were statistically significant differences between the two studied groups in terms of functional and aesthetic limitations, with p-values 0.010* and 0.014* respectively. On the other hand, there were no significant differences in chewing limitation and social disability, with p-values of 0.572 and 0.087 respectively. CONCLUSION: Within the limitations of this study, a full digital workflow for producing maxillary obturator prostheses can increase patient satisfaction with respect to functional, aesthetic, and phonetic outcomes. TRIAL REGISTRATION: This research was registered on www. CLINICALTRIALS: gov in 17-06-2023 with registration number NCT0592081.

Citer ce document

AboShady, M. M., & Amer, M. (2025). Patient satisfaction with conventional versus fully digital obturators fabricated with 3D printing: a randomized crossover trial. BMC Oral Health. https://doi.org/10.1186/s12903-025-06106-y

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 28/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 1

Téléchargements : 0