{# Audit 04/10/2026 : « autre » n'est pas un code de langue ; SPHAERO n'est pas l'éditeur des documents qu'elle héberge ou référence. #} {# citation_pdf_url doit mener à un PDF : un lien vers une page DOI est pénalisé par Google Scholar (avant : tout lien externe). #}
Accès ouvert · CC BY

Comparative Evaluation of CHROMagar COL-APSE, MicroScan Walkaway, ComASP Colistin, and Colistin MAC Test in Detecting Colistin-resistant Gram-Negative Bacteria

Article scientifique 2020 Anglais

Résumé

Colistin has become a critical antibiotic for fatal Gram-negative infections owing to the proliferation of multidrug-resistant carbapenemase-producing bacteria. Thus, cheaper, faster, efficient and easier-to-use colistin diagnostics are required for clinical surveillance, diagnoses and therapeutics. The sensitivity, specificity, major error (ME), very major error (VME), categorial agreement, essential agreement, turnaround time (TAT), average cost, and required skill for four colistin resistance diagnostics viz., CHROMagar COL-APSE, ComASP Colistin, MicroScan, and Colistin MAC Test (CMT) were evaluated against broth microdilution (BMD) using 84 Gram-negative bacterial isolates. A multiplex PCR (M-PCR) was used to screen all isolates to detect the presence of the mcr-1 to mcr-5 genes. A 15-point grading scale was used to grade the tests under skill, ease, processing time etc. mcr-1 was detected by both M-PCR and CMT in a single E. coli isolate, with other PCR amplicons suggestive of mcr-2, -3 and -4 genes being also observed on the gel. The sensitivity and specificity of CHROMagar COL-APSE, MicroScan, and ComASP Colistin, were 82.05% and 66.67%, 92.31% and 76.92%, and 100% and 88.89% respectively. The MicroScan was the most expensive at a cost (per sampe tested) of R221.6 ($15.0), followed by CHROMagar COL-APSE (R118.3; $8.0), M-PCR (R75.1; $5.1), CMT (R20.1; $1.4) and ComASP Colistin (R2.64; $0.2). CHROMagar was the easiest to perform, followed by ComASP Colistin, M-PCR, MicroScan, CMT and BMD whilst M-PCR and MicroScan required higher skill. The ComASP Colistin was the best performing diagnostic test, with low VME and ME, making it recommendable for routine colistin sensitivity testing in clinical laboratories; particularly, in poorer settings. It is however limited by a TAT of 18-24 hours.

Citer ce document

Sekyere, J. O., Sephofane, A. K., & Mbelle, N. (2020). Comparative Evaluation of CHROMagar COL-APSE, MicroScan Walkaway, ComASP Colistin, and Colistin MAC Test in Detecting Colistin-resistant Gram-Negative Bacteria. Scientific Reports. https://doi.org/10.1038/s41598-020-63267-2

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 04/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 4

Téléchargements : 0