{# Audit 04/10/2026 : « autre » n'est pas un code de langue ; SPHAERO n'est pas l'éditeur des documents qu'elle héberge ou référence. #} {# citation_pdf_url doit mener à un PDF : un lien vers une page DOI est pénalisé par Google Scholar (avant : tout lien externe). #}
Accès ouvert · CC BY

Development and validation of an ultraviolet-visible spectrophotometric method for quantifying oxytetracycline for veterinary use

Article scientifique 2023 Anglais

Résumé

Livestock breeding plays a key role in sub-Saharan Africa because it is an important source of highly valued protein in the human diet, and because it is an essential driver for socio-economic development. It represents a form of investment and is also important from a socio-cultural point of view (ceremonies, social position, etc.). Livestock is an important source of income, livelihood, nutrition, and food security. However, livestock breeding faces, among other things, major sanitary constraints. Furthermore, the circulation of non-compliant antibiotics on the market constitutes a major threat to animal health, public health, and the environment. This research aims to develop and validate a UV-vis method for quantifying pharmaceutical oxytetracycline. The method developed was validated following the total error strategy as a decision tool in the accuracy profile. After its completion, the method demonstrated good absolute and relative bias and was within a tolerable interval of [−2%, +2%]. The method was also repeatable with intermediate precision, with respectively lower values than 2% and 4%. We also assessed the recovery and accuracy of the method as fitting with the specification limits. After its validation, the method was quantified in 47 oxytetracycline injectable samples, where we obtained 28 samples complying with specifications and 19 that did not. That led us to conclude that the developed method was validated and appropriate for quantification in terms of the routine quality control of oxytetracycline injection. The method needs to be reviewed and revalidated accordingly for other pharmaceutical presentations.

Citer ce document

Tshibamba, J. M. K., Kakumba, J. M., Mabaya, T. M., Djang’ieng’a, R. M., & Kindenge, J. M. (2023). Development and validation of an ultraviolet-visible spectrophotometric method for quantifying oxytetracycline for veterinary use. Frontiers in Analytical Science. https://doi.org/10.3389/frans.2023.1066348

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 10/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 4

Téléchargements : 0