Evaluation of the biodistribution of [99mTc]Tc-PSMA-GCK01 SPECT/CT in a prospective, intraindividual comparison with [68Ga]PSMA-11 PET/CT for phenotyping in mCRPC prior to PSMA-targeted radioligand therapy
Résumé
Abstract Background PSMA-PET/CT became an important means for prostate cancer management. The high-resolution and signal-to-noise ratio of PET is mandatory in primary staging or biochemical relapse that often present with tiny lesions. PSMA-PET is also used to select patients for PSMA-targeted radioligand-therapy, but scanner availability increasingly becomes a bottleneck. The resolution of PSMA-SPECT/CT might be sufficient to tailor PSMA positive vs. negative disease and would help overcome supply limitations. This prospective, monocentric study evaluates the biodistribution and tumor uptake of [ 99m Tc]Tc-PSMA-GCK01 in an intra-individual head-to-head comparison with [ 68 Ga]PSMA-11 to assess its suitability for phenotyping prior to RLT. Results A cohort of ten patients (median age, 68 y; range, 56–85 y) with advanced-stage, metastatic prostate cancer underwent both unenhanced [ 68 Ga]PSMA-11 PET/CT and [ 99m Tc]Tc-PSMA-GCK01 SPECT/CT scans with a mean time interval of 6 days (± 1). The tracer uptake in malignant lesions and normal organs was assessed visually and semi-quantitatively using spherical VOIs by two nuclear medicine physicians in consensus. Compared to [ 99m Tc]Tc-PSMA-GCK01, [ 68 Ga]PSMA-11 displayed a trend toward higher uptake in normal organs. Renal tracer uptake was significantly higher with [ 68 Ga]PSMA-11 than with [ 99m Tc]Tc-PSMA-GCK01. In the salivary glands and liver, there was no statistically significant difference in uptake between the two tracers, although [ 99m Tc]Tc-PSMA-GCK01 displayed a trend toward lower uptake. Conclusion Our study demonstrates intraindividual comparability of [ 99m Tc]Tc-PSMA-GCK01 and [ 68 Ga]PSMA-11 with respect to normal-organ distribution including typical reference organs such as the liver or salivary glands. If only lesions > 2 cm are considered, [ 99m Tc]Tc-PSMA-GCK01 PSMA-SPECT is a viable, cost-effective alternative to [ 68 Ga]PSMA-11 to stratify patients toward or against PSMA-RLT.
Citer ce document
Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)
Accès au document
Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter
Voir l'article sur le site de la revueLicence et provenance
Licence : CC BY
Notice moissonnée depuis OpenAlex le 02/10/2026. Le document reste hébergé par sa source.
Voir le document à la source →