Accès ouvert · CC BY

Moistube irrigation fouling due to anaerobic filtered effluent (AF) and horizontal flow constructed wetland (HFCW) effluent

Article scientifique 2021 Sciences de la Terre et de l'environnement › Sciences de l'environnement (OCDE 1.5) Anglais

Résumé

The study assessed the suitability of two effluent types, namely anaerobic filtered (AF) and horizontal flow constructed wetland (HFCW) effluent for Moistube irrigation (MTI). Secondary to this, the study determined the plugging coefficients (α) on MTI for the respective effluents. The feed water was supplied from a raised tank (3.5 m), and mass-flow rates were recorded at 15 min intervals using an electronic balance. The effluent feed water concentrations and experimental room temperature (25 °C ± 1 °C) were continuously monitored and kept constant. Hermia's models based on the [Formula: see text] coefficient was used to select the best fitting fouling mechanism model and, consequently, the plugging coefficients. In addition, microbial colony analysis and scanning electron microscopy (SEM) analysis was carried out to assess the composition of the deposited sediment (DS) and adhered bacterial film (ABF) onto the MTI lateral. The study revealed that MTI pore blocking was a complex phenomenon described by complete pore-blocking model ([Formula: see text] ≥ 0.50). Discharge followed an exponential decay with early fouling observed on AF effluent because of a high concentration of total suspended solids (TSS) and dissolved organic matter (DOM). Discharge declined by 50% after 20 and 10 h of intermittent operation for AF and HFCW effluent, respectively. The α for each effluent (foulant) were [Formula: see text] = 0.07 and [Formula: see text] = 0.05, respectively, for AF and HFCW. The microbial analysis revealed bacterial aggregation structures that contributed to pore blocking. SEM imaging revealed complete surface coverage by deposited sediment. It is concluded that water quality determines the operation life span of MTI, and the two effluents promote accelerated MTI pore fouling or blocking. Continuous use without flushing the MTI will promote membrane degradation and reduced discharge efficiency. Additional filtration can potentially mitigate the membrane degradation process.

Citer ce document

Dirwai, T. L., Senzanje, A., Mabhaudhi, T., & Buckley, C. (2021). Moistube irrigation fouling due to anaerobic filtered effluent (AF) and horizontal flow constructed wetland (HFCW) effluent. Scientific Reports. https://doi.org/10.1038/s41598-021-86737-7

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 05/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 15

Téléchargements (hors robots) : 0

Méthode de comptage