Accès ouvert · CC BY

Diagnostic performance of optical coherence tomography macular ganglion cell inner plexiform layer and retinal nerve fiber layer thickness in glaucoma suspect and early glaucoma patients at St. Paul’s hospital millennium medical college, Addis Ababa, Ethiopia

Article scientifique 2023 Sciences de la santé Anglais

Résumé

PURPOSE: To evaluate glaucoma diagnostic performance of ganglion cell inner plexiform layer and retinal nerve fiber layer parameters measured with cirrus HD optical coherence tomography (OCT). METHOD: Total of 188 eyes were included in our study. 49 eyes of healthy controls, 70 glaucoma suspect eyes and 69 early glaucomatous eyes. Complete ophthalmic examination was done including visual field test (with Humphrey field analyzer) and OCT scanning of ganglion cell inner plexiform layer (GCIPL) and retinal nerve fiber layer (RNFL) in different quadrants. Sensitivity, specificity and area under the receiver operating characteristic curve (AUROC) of each parameter was calculated to provide diagnostic ability between normal controls, glaucoma suspects or early glaucoma. RESULT: GCIPL and RNFL parameters had strong power in discriminating early glaucoma from healthy controls with all having AUROC of above 0.76. Of all the GCIPL and RNFL parameters, the only variable that could discriminate between glaucoma suspect and healthy controls was the combined parameter by OR-logic approach. Of all the parameters, the average and nasal RNFL parameters had the strongest power in discriminating between the two with AUROC of 0.81. All parameters had an overall good diagnostic performance with excellent sensitivity but the specificity was relatively poor. The combined parameter had the best specificity (62.2%) with excellent sensitivity (93.5%). CONCLUSION: Nasal RNFL parameters had the strongest power in discriminating between glaucoma suspect and healthy controls and the OR-logic combination of RNFL and GCIPL provides better diagnostic performance than single GCIPL, RNFL or ONH parameter.

Citer ce document

Abera, A., & Gessesse, G. W. (2023). Diagnostic performance of optical coherence tomography macular ganglion cell inner plexiform layer and retinal nerve fiber layer thickness in glaucoma suspect and early glaucoma patients at St. Paul’s hospital millennium medical college, Addis Ababa, Ethiopia. PLoS ONE. https://doi.org/10.1371/journal.pone.0263959

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 10/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 11

Téléchargements (hors robots) : 0

Méthode de comptage