{# Audit 04/10/2026 : « autre » n'est pas un code de langue ; SPHAERO n'est pas l'éditeur des documents qu'elle héberge ou référence. #} {# citation_pdf_url doit mener à un PDF : un lien vers une page DOI est pénalisé par Google Scholar (avant : tout lien externe). #}
Accès ouvert · CC BY

Factors which contributed for low quality sputum smears for the detection of acid fast bacilli (AFB) at selected health centers in Ethiopia: A quality control perspective

Article scientifique 2018 Anglais

Résumé

OBJECTIVES: Quality of tuberculosis (TB) microscopy diagnosis is not a guarantee despite implementation of External Quality Assurance (EQA) service in all laboratories of health facilities. Hence, we aimed at evaluating the technical quality and the findings of sputum smear microscopy for acid fast bacilli (AFB) at health centers in Hararge Zone, Oromia Region, Ethiopia. METHODS: A cross-sectional study was carried out between July 8, 2014 and July 7, 2015.A pre-tested structured questionnaire was used to collect data. Lot Quality Assurance Sampling (LQAS) method was put into practice for collecting all necessary sample slides. Data were analyzed by using SPSS (Statistical Package for Social Sciences) version 20 software. P-value < 0.05 was considered as statistically significant. RESULTS: Of the total55 health center laboratories which had been assessed during the study period, 20 (36.4%) had major technical errors; 13 (23.6%) had 15 false negative results and 17 (30.9%) had 22 false positive results. Moreover, poor specimen quality, smear size, smear thickness, staining and evenness were indicated in 40 (72.7%), 39 (70.9%), 37 (67.3%), 27(49.1%) and 37 (67.3%) of the collected samples, respectively. False negative AFB findings were significantly associated with lack of Internal Quality Control (IQC) measures (AOR (Adjusted Odds Ratio): 2.90 (95% CI (Confidence Interval): 1.25,6.75) and poor staining procedures (AOR: 2.16(95% CI: 1.01, 5.11). CONCLUSIONS: The qualities of AFB smear microscopy reading and smearing were low in most of the laboratories of the health centers. Therefore, it is essential to strength EQA program through building the capacity of laboratory professionals.

Citer ce document

Mekonen, A., Ayele, Y., Berhan, Y., Woldeyohannes, D., Erku, W., & Sisay, S. (2018). Factors which contributed for low quality sputum smears for the detection of acid fast bacilli (AFB) at selected health centers in Ethiopia: A quality control perspective. PLoS ONE. https://doi.org/10.1371/journal.pone.0198947

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 30/08/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 4

Téléchargements : 0