Flow-S enables field-based detection of low-intensity Schistosoma infections for monitoring and evaluation of control programs

Article scientifique 2026 Sciences de la santé › Santé publique (OCDE 3.3) Anglais

Résumé

Introduction Schistosomiasis remains a major public health challenge, particularly in sub-Saharan Africa. Detecting low-intensity infections is difficult because conventional parasitological methods lack sufficient sensitivity. Circulating anodic antigen (CAA), a genus-specific biomarker released by Schistosoma worms, enables detection of active Schistosoma infections. However, existing CAA assays require laboratory-based sample processing. We evaluated Flow-S, a field-deployable device for high-sensitivity quantitative CAA detection directly from large-volume, untreated urine samples. Flow-S integrates CAA concentration and quantitative upconverting reporter particle lateral flow (UCP-LF) detection with a portable standalone battery-powered reader for field-use. Methods A prospective study was conducted by local healthcare staff in a remote Schistosoma haematobium -endemic low-to-moderate infection setting. Fresh urine samples (n = 158) from women of reproductive age were analyzed using Flow-S. Paired urine, serum, and stool samples were examined by urine filtration microscopy, Kato-Katz (to exclude S. mansoni ), and laboratory-based UCP-LF CAA reference assays (serum SCAA20 and urine UCAA hT 417). A composite reference standard (CRS) classified individuals as infected when eggs or either reference CAA assay was positive. Flow-S performance was evaluated against the CRS and further assessed using latent class analysis (LCA). Results Complete datasets were available for 115 samples. Flow-S achieved an area under the receiver operating characteristic (ROC) curve of 0.92 and detected all egg-positive infections. Using a positivity threshold of 1.10 pg/mL, Flow-S achieved 80.8% sensitivity and 96.6% specificity, meeting the World Health Organization ideal target product profile requirements for monitoring and evaluation of schistosomiasis control programs. Latent class analysis provided complementary model-based evidence consistent with the high discriminatory performance of Flow-S observed using the composite reference standard. Conclusions Flow-S enables quantitative, field-deployable detection of S. haematobium infections directly from untreated large-volume urine without laboratory pre-treatment. Its high analytical sensitivity and diagnostic performance support its potential for detecting low-intensity infections. At an operational threshold of 1.10 pg/mL, Flow-S met the WHO TPP ideal targets for monitoring and evaluation and showed potential for cost-effective surveillance strategies, including pooled-sample screening for schistosomiasis control and elimination programs.

Citer ce document

Jong, D. D., Carrell, C., Maganga, J. K., Shigella, P. S., Mhango, L., Hoekstra, P. T., Dam, G. J. V., Mullins, B., Changalucha, J., Downs, J. A., Warrick, J. W., & Corstjens, P. L. A. M. (2026). Flow-S enables field-based detection of low-intensity Schistosoma infections for monitoring and evaluation of control programs. Frontiers in Parasitology. https://doi.org/10.3389/fpara.2026.1974692

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 16/11/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 2

Téléchargements (hors robots) : 0

Méthode de comptage