{# Audit 04/10/2026 : « autre » n'est pas un code de langue ; SPHAERO n'est pas l'éditeur des documents qu'elle héberge ou référence. #} {# citation_pdf_url doit mener à un PDF : un lien vers une page DOI est pénalisé par Google Scholar (avant : tout lien externe). #}
Accès ouvert · CC BY

Comparison of three-fold converted hematocrit and micro-hematocrit in pregnant women

Article scientifique 2019 Anglais

Résumé

BACKGROUND: Anemia is one of the common complications of pregnancy. Hemoglobin concentration, Hematocrit, and Red cell count are laboratory tests used to diagnose anemia. In are source poor setting, there is a practice of using three-fold converted Hematocrit. This study is designed to assess the association and acceptability of three-fold converted Hematocrit as compared to the standard Micro-hematocrit method, in pregnant women. METHOD: The cross-sectional study conducted from May 18 to June 12, 2018 involved 200 pregnant women who visited the Laboratory for a Hematocrit test. Three milliliter of venous blood was collected with EDTA tube to determine Hematocrit by the Micro-hematocrit method and Hemoglobin concentration measured by a HemoCue Hemoglobin B analyzer. A scatter plot, correlation coefficient, Bland and Altman plot, and Area under curve were employed to assess the agreement and acceptability of the calculated Hematocrit as compared to the standard Micro-hematocrit. RESULT: The correlation coefficient, Intraclass correlation coefficient and concordance correlation coefficient were 0.91, 0.94, and 0.89, respectively. The Bland and Altman plot showed a mean difference of 0.94 with the limit of agreement ranges from 0.6 to 1.3. The area under the receiver operating characteristics with cut-off point of Hematocrit <33% was 0.86. The sensitivity and specificity of the calculated method was 95.5% and 71.4%, respectively. CONCLUSION: Generally there is excellent association between the two methods. The two methods were identical within inherent imprecision of both methods. Hence, the Hematocrit value, threefold calculated from the Hemoglobin was found to be acceptable to diagnose anemia in pregnant women.

Citer ce document

Kiya, G. T., & Zewudie, F. M. (2019). Comparison of three-fold converted hematocrit and micro-hematocrit in pregnant women. PLoS ONE. https://doi.org/10.1371/journal.pone.0220740

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 02/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 1

Téléchargements : 0