Assessment of the modulation degrees of intensity-modulated radiation therapy plans

Article scientifique 2018 Anglais

Résumé

To evaluate the modulation indices (MIs) for predicting the plan delivery accuracies of intensity-modulated radiation therapy (IMRT) plans. A total of 100 dynamic IMRT plans that used TrueBeam STx and 102 dynamic IMRT plans that used Trilogy were selected. For each plan, various MIs were calculated, which included the modulation complexity score (MCS), plan-averaged beam area (PA), plan-averaged beam irregularity (PI), plan-averaged beam modulation (PM), MI quantifying multi-leaf collimator (MLC) speeds (MI s ), MI quantifying MLC acceleration (MI a ), and MI quantifying MLC acceleration and segment aperture irregularity (MI c,IMRT ). To determine plan delivery accuracy, global gamma passing rates, MLC errors of log files, and dose-volumetric parameter differences between original and log file-reconstructed IMRT plans were obtained. To assess the ability of each MI for predicting plan delivery accuracy, Spearman’s rank correlation coefficients ( r s ) between MIs and plan delivery accuracy measures were calculated. PI showed moderately strong correlations with gamma passing rates in MapCHECK2 measurements of both TrueBeam STx and Trilogy ( r s = − 0.591 with p < 0.001 and − 0.427 with p < 0.001 to with gamma criterion of 2%/2 mm, respectively). For ArcCHECK measurements, PI also showed moderately strong correlations with the gamma passing rates in the ArcCHECK measurements of TrueBeam STx and Trilogy ( r s = − 0.545 with p < 0.001 and r s = − 0.581 with p < 0.001 with gamma criterion of 2%/2 mm, respectively). The PI showed the second strongest correlation with MLC errors in both TrueBeam STx and Trilogy ( r s = 0.861 with p < 0.001 and r s = 0.767 with p < 0.001, respectively). In general, the PI showed moderately strong correlations with every plan delivery accuracy measure. The PI showed moderately strong correlations with every plan delivery accuracy measure and therefore is a useful predictor of IMRT delivery accuracy.

Citer ce document

Park, S. Y., Kim, J.-I., Chun, M., Ahn, H., & Park, J. M. (2018). Assessment of the modulation degrees of intensity-modulated radiation therapy plans. Radiation Oncology. https://doi.org/10.1186/s13014-018-1193-9

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 31/08/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 6

Téléchargements : 0