Accès ouvert · CC BY

Detection and Quantification of Mycobacterium tuberculosis in the Sputum of Culture-Negative HIV-infected Pulmonary Tuberculosis Suspects: A Proof-of-Concept Study

Article scientifique 2016 Sciences de la santé Anglais

Résumé

RATIONALE: Rapid diagnosis of pulmonary tuberculosis (TB) is critical for timely initiation of treatment and interruption of transmission. Yet, despite recent advances, many patients remain undiagnosed. Culture, usually considered the most sensitive diagnostic method, is sub-optimal for paucibacillary disease. METHODS: We evaluated the Totally Optimized PCR (TOP) TB assay, a new molecular test that we hypothesize is more sensitive than culture. After pre-clinical studies, we estimated TOP's per-patient sensitivity and specificity in a convenience sample of 261 HIV-infected pulmonary TB suspects enrolled into a TB diagnostic study in Mbarara, Uganda against MGIT culture, Xpert MTB/RIF and a composite reference standard. We validated results with a confirmatory PCR used for sequencing M. tuberculosis. MEASUREMENTS AND RESULTS: Using culture as reference, TOP had 100% sensitivity but 35% specificity. Against a composite reference standard, the sensitivity of culture (27%) and Xpert MTB/RIF (27%) was lower than TOP (99%), with similar specificity (100%, 98% and 87%, respectively). In unadjusted analyses, culture-negative/TOP-positive patients were more likely to be older (P<0·001), female (P<0·001), have salivary sputum (P = 0·05), sputum smear-negative (P<0.001) and less advanced disease on chest radiograph (P = 0.05). M. tuberculosis genotypes identified in sputum by DNA sequencing exhibit differential growth in culture. CONCLUSIONS: These findings suggest that the TOP TB assay is accurately detecting M. tuberculosis DNA in the sputum of culture-negative tuberculosis suspects. Our results require prospective validation with clinical outcomes. If the operating characteristics of the TOP assay are confirmed in future studies, it will be justified as a "TB rule out" test.

Citer ce document

Madico, G., Mpeirwe, M., White, L. F., Vinhas, S. A., Orr, B., Orikiriza, P., Miller, N. S., Gaeddert, M., Mwanga‐Amumpaire, J., Palaci, M., Kreiswirth, B. N., Straight, J., Dietze, R., Boum, Y., & Jones‐López, E. C. (2016). Detection and Quantification of Mycobacterium tuberculosis in the Sputum of Culture-Negative HIV-infected Pulmonary Tuberculosis Suspects: A Proof-of-Concept Study. https://doi.org/10.1371/journal.pone.0158371

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 25/08/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 14

Téléchargements (hors robots) : 0

Méthode de comptage