{# Audit 04/10/2026 : « autre » n'est pas un code de langue ; SPHAERO n'est pas l'éditeur des documents qu'elle héberge ou référence. #} {# citation_pdf_url doit mener à un PDF : un lien vers une page DOI est pénalisé par Google Scholar (avant : tout lien externe). #}
Accès ouvert · CC BY

Improved Controller and Design Method for Grid-Connected Three-Phase Differential SEPIC Inverter

Article scientifique 2021 Anglais

Résumé

Single-ended primary-inductor converter (SEPIC) based differential inverters (SEPIC-BDI) have received wide concerns in renewable energy applications due to their modularity, galvanic isolation, decreased power stages, continuous input current, and step up/down capability. However, its design still has several challenges related to component design, the existence of complex right half plane (RHP) zeros, and increased sensitivity to component mismatches. In this context, this paper presents an improved control and enhanced design method for the three-phase SEPIC-BDI for grid-tied applications. A generalized static linearization approach (SLA) is proposed to mitigate the low-order harmonics. It practically simplifies the control complexity and decreases the required control loops and sensor circuits. The mismatch between the SEPIC converters in each phase is highly mitigated due to the independent operation of the SLA in each phase and the output dc offset currents are reduced. The proposed enhanced design methodology modifies the SEPIC open-loop transfer function by moving the complex RHP zeros to the left half-plane (LHP). Therefore, a simple proportional-integral (PI) controller effectively maintains converter stability without adding higher-order compensators in the literature. Moreover, a straightforward integrator in the control loop eliminates the negative sequence harmonic component (NSHC) and provides a low computational burden. Simulations and experimental results based on 200V, 1.6 kW, 50 kHz prototype with silicon carbide (SiC) devices are provided to validate the effectiveness of the proposed work. The results show that the proposed controller and design method achieve pure output current waveforms at various operating points of the inverter and dc voltage variations.

Citer ce document

Shawky, A., Takeshita, T., Sayed, M. A., Aly, M., & Ahmed, E. M. (2021). Improved Controller and Design Method for Grid-Connected Three-Phase Differential SEPIC Inverter. IEEE Access. https://doi.org/10.1109/access.2021.3072489

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 05/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 1

Téléchargements : 0