Accès ouvert · CC BY

An Experimental and Numerical Investigation of Air Entrainment through Inclined Ventilated Submerged Orifices with Different Geometries

Article scientifique 2026 Sciences de l'ingénieur et technologies Autre

Résumé

Air entrainment through submerged ventilated orifices plays an important role in hydraulic structures and air–water mixing systems, where the entrained air discharge depends on both hydraulic and geometric parameters. This study experimentally investigated the combined effects of orifice geometry, characteristic dimension, inclination angle, Reynolds number, and air-inlet location on air-entrainment performance. More than 500 experimental tests were conducted using circular, square, and equilateral triangular orifices with three characteristic dimensions, four inclination angles (0°, 15°, 30°, and 45°), three air-inlet locations, and five water-flow rates ranging from 29.44 to 88.31 L/min. Representative operating conditions were additionally simulated using Computational Fluid Dynamics (CFD) to validate the experimental measurements. The results showed that the air-to-water flow-rate ratio (qa/qw) generally decreased with increasing Reynolds number due to the increasing dominance of liquid inertia. Orifice geometry significantly influenced air entrainment, with triangular orifices consistently outperforming the other configurations. Smaller characteristic dimensions generally enhanced air entrainment under the baseline air-inlet configuration, whereas relocating the air inlet farther downstream altered the flow structure and produced pronounced entrainment peaks for triangular orifices under selected operating conditions. CFD predictions showed good agreement with the experimental measurements, with deviations generally below 5% for inclination angles of 0° and 15°, and moderately increasing at larger inclination angles. The highest air-entrainment performance was achieved using the largest triangular orifice (T3) at an inclination angle of 30° with the air inlet located at Pipe 3 and a water-flow rate of 29.44 L/min, producing qa/qw = 2.21, corresponding to a normalized performance index of Q = 13.04.

Citer ce document

Salih, M. H., Abdelaal, M. A., Mohammed, R. F., Elshimy, A. A., & Mahmoud, A. H. (2026). An Experimental and Numerical Investigation of Air Entrainment through Inclined Ventilated Submerged Orifices with Different Geometries. Engineering Technology & Applied Science Research. https://doi.org/10.48084/etasr.21382

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 12/10/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 8

Téléchargements (hors robots) : 0

Méthode de comptage