Tissue surface adaptation and retention of digital obturator after one year of use

Article scientifique 2024 Sciences de la santé Anglais

Résumé

BACKGROUND: Effect of aging on tissue adaptability and retention of digital obturator is still under investigation. METHODS: A maxillary Armany (class I) epoxy reference model was scanned to fabricate digital obturator fabricated from milled Co-Cr framework and 3D printed bulb. A color map of the scanned reference and digital obturator was made using Geomagic software to evaluate the accuracy of fit before and after cyclic loading using ROBOTA chewing simulator at 37,500, 75,000 and 150,000 cycles to simulate clinically 3-, 6- and 12-months chewing condition. Insertion-removal condition simulating the placement and removal of the obturator was done using repeated 360, 720 and 1440 cycles and retention was evaluated before and after the repeated cycles. Data were collected, tabulated and statistically analyzed using Statistical Package for Social Sciences (IBM SPSS Statistics 26). Student t-test and multi variable ANOVA test were used to detect significance. P-value < 0.05 was considered significant difference. RESULTS: For retention test: There was a significant difference between baseline and 3, 6 and12 months. For the tissue surface adaptation test: There was significant difference at all measured areas (P-value < 0.05) before and after application of load. CONCLUSION: digitally designed and fabricated obturator was highly retentive and has excellent tissue surface adaptation upon fabrication, After application of load; reduction of retention and lack of tissue adaptation were resulted. THE CLINICAL IMPLICATION: of this manuscript is that digital obturator can be used successfully with the shortcomings of loosening retention and adaptation afterwhile. So, clinical trials should investigate the clinical acceptance of these shortcomings.

Citer ce document

khalaf, K. M. A. E. S., Rashad, H. M. A., & Mostafa, T. (2024). Tissue surface adaptation and retention of digital obturator after one year of use. BMC Oral Health. https://doi.org/10.1186/s12903-024-04639-2

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 27/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 10

Téléchargements (hors robots) : 0

Méthode de comptage