{# Audit 04/10/2026 : « autre » n'est pas un code de langue ; SPHAERO n'est pas l'éditeur des documents qu'elle héberge ou référence. #} {# citation_pdf_url doit mener à un PDF : un lien vers une page DOI est pénalisé par Google Scholar (avant : tout lien externe). #}
Accès ouvert · CC BY

Comparison between refractive outcomes of femtosecond laser-assisted cataract surgery and standard phacoemulsification

Article scientifique 2020 Anglais

Résumé

BACKGROUND: To compare the visual and refractive outcomes of femtosecond laser assisted cataract surgery (FLACS) using Victus platform (Technolas Bausch and Lomb (B&L), Munich, Germany) and conventional phacoemulsification cataract surgery (CPCS). METHODS: A retrospective study of 100 eyes operated for cataract. FLACS was performed in 50 eyes and CPCS was done in another 50 eyes. Preoperative and 6 months postoperative visual and refractive evaluation (efficacy, safety, predictability, and surgically induced astigmatism) as well as higher-order aberrations were analyzed. Efficacy index which equals post-operative mean of uncorrected distance visual acuity (UDVA) divided by preoperative mean corrected distance visual acuity (CDVA) was calculated in both groups. Safety index equals post-operative mean of corrected distance visual acuity (CDVA) divided by preoperative mean CDVA. RESULTS: Logarithm of the Minimum Angle of Resolution (LogMAR), UDVA improved in both groups after surgery (p < 0.05). It was 0.23 ± 0.20 and 0.291 ± 0.311 log MAR in FLACS and CPCS groups respectively. Safety index was 1.777 in FLACS group and 1.744 in CPCS groups showing high degree of safety of both measures. Mean surgically induced astigmatism (SIA) was 0.35 ± 0.67 D and 0.901 ± 0.882 D in FLACS and CPCS groups respectively (p = 0.015). The post-operative comparison between both groups was in favor of CPCS group vs. FLACS group regarding total aberrations (0.563 ± 0.386 vs. 0.91 ± 1.20) (p = 0.03), while low order aberrations were significantly less in FLACS group vs. CPCS group (0.64 + 0.63 vs. 2.07 + 3.15) (p = 0.027). RMS high order aberration was higher in FLACS group vs. CPCS group but of no statistical significance 0.54 ± 0.96 vs. 0.328 ± 0.360 (p = 0.082). CONCLUSION: Femtosecond laser -assisted cataract surgery was a safe and precise procedure but enhanced visual outcomes only minimally when compared to conventional cataract surgery in experienced hands. Both FLACS and manual surgeries can achieve a high efficacy, predictability and safety with slight superior outcomes in FLACS. TRIAL REGISTRATION NUMBER: PACTR201804003256258 (date: 27 Mar 2018) Available at: https://pactr.samrc.ac.za/.

Citer ce document

Shaheen, M. S., AbouSamra, A., Helaly, H. A., Said, A., & Elmassry, A. (2020). Comparison between refractive outcomes of femtosecond laser-assisted cataract surgery and standard phacoemulsification. BMC Ophthalmology. https://doi.org/10.1186/s12886-019-1277-9

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 04/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 3

Téléchargements : 0