Accès ouvert · CC BY

Calibration-free picosecond LIPS for quantifying heavy metals in soils near Egyptian industrial sites

Article scientifique 2025 Sciences de l'ingénieur et technologies Anglais

Résumé

Abstract Excessive fertilizer and chemical usage have led to soil contamination by toxic heavy metals near the Abu-Zaabal industrial complex in Egypt. We introduce a groundbreaking calibration-free methodology using ultrafast Picosecond Laser-Induced Plasma Spectroscopy (CF-Ps-LIPS) for quantifying contaminant elements (Cd, Zn, Fe, Ni) in soils near Egypt’s Abu-Zaabal industrial complex. This study pioneers applying 170 ps laser pulses (Nd: YAG, 1064 nm) to achieve calibration-free analysis, eliminating matrix-matched standards and offering ± 1% agreement with ICP-OES. By integrating plasma diagnostics (electron density N e = 1.2–1.5 × 10 17 cm − 3 and temperature T e = 8508–10,275 K), we establish CF-Ps-LIPS as a rapid, minimally invasive tool for on-site environmental monitoring, validated through spatial contamination gradients linked to wind patterns. Concentrations of Cd (25.1–136.5 mg/kg), Zn (19.8–146.9 mg/kg), Fe (59.7–62 mg/kg), and Ni (119.4–157.8 mg/kg) were analyzed across seven sampling sites. The seventh site was used as a test sample of unknown concentration to validate CF-Ps-LIPS. Utilizing the Boltzmann distribution with plotting techniques enables precise plasma electron density and temperature determination under local thermodynamic equilibrium (LTE) conditions. The CF-Ps-LIPS study revealed significant concentration variations dependent on trace metal type, sampling location, and facility orientation. The CF-Ps-LIPS method provides calibration-free, rapid, and accurate detection of metal contaminants in Egyptian soils for the first time. This methodology significantly advances environmental monitoring and soil contamination analysis, allowing on-site assessments with higher efficiency and reliability.

Citer ce document

El-Saeed, M., Tawfik, W., Khalil, A. A. I., Mubarak, M., & Fikry, M. (2025). Calibration-free picosecond LIPS for quantifying heavy metals in soils near Egyptian industrial sites. Scientific Reports. https://doi.org/10.1038/s41598-025-04395-5

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 28/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 6

Téléchargements (hors robots) : 0

Méthode de comptage