Accès ouvert · CC BY

Can passive leg raise predict the response to fluid resuscitation in ED?

Article scientifique 2022 Sciences de la santé Anglais

Résumé

OBJECTIVE: Passive leg raise (PLR) can be used as a reversible preload challenge to stratify patients according to preload response. We aim to evaluate the accuracy of PLR, monitored by a non-invasive cardiac output monitor in predicting to response to fluid resuscitation in emergency department (ED). METHODS: We recruited adult patients planned to receive a resuscitation fluid bolus. Patients were monitored using a thoracic electrical bioimpedance (TEB) cardiac output monitor (Niccomo, Medis, Germany). A 3-min PLR was carried out before and after fluid infusion. Stroke volume changes (ΔSV) were calculated and a positive response was defined as ≥ 15% increase. RESULTS: We recruited 39 patients, of which 37 were included into the analysis. The median age was 63 (50-77) years and 19 patients were females. 17 patients (46%) were fluid responders compared to 11 (30%) with positive response to PLR1. ΔSV with PLR1 and fluid bolus showed moderate correlation (r = 0.47, 95% confidence interval, CI 0.17-0.69) and 62% concordance rate. For the prediction of the response to a fluid bolus the PLR test had a sensitivity of 41% (95% CI 22-64) and specificity of 80% (95% CI 58-92) with an area under the curve of 0.59 (95% CI 0.41-0.78). None of the standard parameters showed a better predictive ability compared to PLR. CONCLUSION: Using TEB, ΔSV with PLR showed a moderate correlation with fluid bolus, with a limited accuracy to predict fluid responsiveness. The PLR test was a better predictor of fluid responsiveness than the parameters commonly used in emergency care (such as heart rate and blood pressure). These data suggest the potential for a clinical trial in sepsis comparing TEB monitored, PLR directed fluid management with standard care.

Citer ce document

Elwan, M., Roshdy, A., Elsharkawy, E., Eltahan, S., & Coats, T. (2022). Can passive leg raise predict the response to fluid resuscitation in ED?. BMC Emergency Medicine. https://doi.org/10.1186/s12873-022-00721-6

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 09/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Autres versions

Statistiques

Consultations (hors robots) : 16

Téléchargements (hors robots) : 0

Méthode de comptage