{# Audit 04/10/2026 : « autre » n'est pas un code de langue ; SPHAERO n'est pas l'éditeur des documents qu'elle héberge ou référence. #} {# citation_pdf_url doit mener à un PDF : un lien vers une page DOI est pénalisé par Google Scholar (avant : tout lien externe). #}
Accès ouvert · CC BY

Retention of zirconia crowns to titanium bases with straight versus angled screw access channels: an invitro study

Article scientifique 2023 Anglais

Résumé

BACKGROUND: The aim of this study was to assess the impact of abutments with angled screw access channel on the retention of zirconia crowns. METHODS: Seven implant replicas were inserted in epoxy resin blocks. Fourteen zirconia crowns for central incisor tooth were digitally fabricated and cemented to titanium bases (Ti-bases) with resin cement. Titanium bases were categorized into 2 groups (n = 7). Control group (Group STA) included straight screw access channel abutments. Study group (Group ASC) included angled screw access channel abutments. Following aging (5 °C-55 °C, 60 s; 250,000 cycles, 100 N, 1.67 Hz), the pull-off forces (N) were recorded by using retention test (1 mm/min). Types of failure were defined as (Type 1; Adhesive failure when luting agent predominantly remained on the Ti-base surface (> 90%); Type 2; Cohesive failure when luting agent remained on both Ti-base and crown surfaces; and Type 3; Adhesive failure when luting agent predominantly remained on the crown (> 90%). Statistical analysis was conducted by using (IBM SPSS version 28). Normality was checked by using Shapiro Wilk test and Q-Q plots. Independent t-test was then used to analogize the groups. RESULTS: Mean ± standard deviation of retention force records ranged from 1731.57 (63.68) N (group STA) to 1032.29 (89.82) N (group ASC), and there was a statistically significant variation between the 2 groups (P < .05). Failure modes were Type 2 for group STA and Type 3 for group ASC. CONCLUSIONS: The retention of zirconia crowns to abutments with a straight screw access channel is significantly higher than abutments with angled screw access channel.

Citer ce document

Ibrahim, E., Khamis, M. M., Ezzelarab, S., & Abdel-Hamid, A. M. (2023). Retention of zirconia crowns to titanium bases with straight versus angled screw access channels: an invitro study. BMC Oral Health. https://doi.org/10.1186/s12903-023-03177-7

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 26/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 1

Téléchargements : 0