Evaluation of implanted perforated lacrimal punctal plugs using anterior segment optical coherence tomography

Article scientifique 2021 Anglais

Résumé

PURPOSE: Evaluation of the patency and position of perforated lacrimal punctal plugs implanted for treating punctal stenosis together with quantitative assessment of the precorneal tear film using anterior segment optical coherence tomography (AS-OCT). METHODS: In a prospective study, the lower punctum of 54 eyes of 29 patients implanted with perforated punctal plugs were examined using AS-OCT during the early postoperative period. Preoperative tear meniscus height (TMH) and tear meniscus area (TMA) were evaluated. Postoperatively, the patency of the plug, its position, TMH and TMA were evaluated, and the results were correlated with postoperative epiphora. Munk scale was used for epiphora grading. RESULTS: Using AS-OCT, 48 (88.9%) plugs were found in proper position while 6 (11.1%) were rotated. The lumen of the plugs was completely patent in 47 (87%) plugs, partially obstructed in 2 (3.7%) plugs and completely occluded in 5 (9.2%) plugs. There was a statistically significant postoperative decrease of TMH and TMA (P < 0.001) and postoperative epiphora Munk score (P < 0.001). CONCLUSION: AS-OCT is a valuable, reliable, and noninvasive investigative tool that can detect the proper positioning, patency, and contents of the implanted perforated lacrimal punctal plugs in addition to measurement of TMH and TMA. Trial registration ClinicalTrials.gov ID: NCT04624022, https://clinicaltrials.gov/ct2/show/NCT04624022.

Citer ce document

Abdallah, R. M. A., Elshafei, A. M. K., & AttaAllah, H. R. (2021). Evaluation of implanted perforated lacrimal punctal plugs using anterior segment optical coherence tomography. Eye and Vision. https://doi.org/10.1186/s40662-021-00259-x

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 05/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 5

Téléchargements : 0