Effect of urine storage conditions on circulating anodic antigen detection using the UCP-LF CAA test

Article scientifique 2026 Sciences de la santé › Santé publique (OCDE 3.3) Anglais

Résumé

Introduction Schistosomiasis is a parasitic neglected tropical disease that remains a major public health problem in many African countries. Accurate diagnosis is essential for control, surveillance and elimination efforts. Conventional parasitological methods have limited sensitivity, particularly in low-intensity infections commonly observed after treatment or in low-endemic settings. Circulating anodic antigen (CAA), released by live Schistosoma worms, is a highly sensitive and specific marker of active infection. The up-converting reporter particle lateral flow (UCP-LF) CAA test enables non-invasive urine-based diagnosis and is increasingly applied in low-endemic and near-elimination settings. For operational feasibility, urine samples may need to be stored before testing, but the effect of different storage conditions on CAA detection has not been systematically evaluated. Methods We investigated the effect of freezing and non-frozen storage on urine CAA detection using the UCP-LF CAA test, compared with freshly tested urine. The study was conducted among school-aged children in a near-elimination Schistosoma haematobium setting on Pemba, Tanzania. A total of 272 urine samples were tested fresh and after freezing at -20 °C for 5-7 days. For a subset of 153 samples with sufficient urine available, an additional aliquot was stored under non-frozen conditions (4-25 °C) and tested approximately 5 weeks after collection. Results CAA positivity decreased from 44/272 (16.2%) in fresh urine to 35/272 (12.9%) after freezing. In the subset, positivity was 20/153 (13.1%) in fresh, 16/153 (10.5%) in frozen, and 24/153 (15.7%) in non-frozen stored urine. CAA concentrations showed strong correlation between storage conditions (Spearman’s ρ = 0.86–0.93, p<0.0001). Freezing was associated with a small but significant reduction in CAA positivity (p=0.004), while CAA concentrations showed a non-significant trend towards lower values after freezing. Non-frozen stored samples showed generally comparable results to fresh urine. Discussion/Conclusion In conclusion, these findings suggest that flexible urine storage strategies may be feasible for delayed centralized CAA testing, although freezing may result in loss of detection among samples with CAA concentrations close to the assay cut-off.

Citer ce document

Hoekstra, P. T., Dam, G. J. V., Blokland-Flink, M., Jong, D. D., Ali, S. M., Ali, M. N., Ndum, N. C., Knopp, S., Corstjens, P. L. A. M., & Lieshout, L. V. (2026). Effect of urine storage conditions on circulating anodic antigen detection using the UCP-LF CAA test. Frontiers in Parasitology. https://doi.org/10.3389/fpara.2026.1894516

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 12/10/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 12

Téléchargements (hors robots) : 0

Méthode de comptage