Green first derivative synchronous spectrofluorimetric determination of lacidipine and its acid degradation product in plasma and mixtures
Résumé
Abstract One of the main objectives of this study is to find an analysis method that has a low environmental and health impact and contributes to achieving sustainability. A simple and sensitive method was established for determination of lacidipine in pure active pharmaceutical ingredient, pharmaceutical formulation and spiked human plasma in presence of its acid induced degradation product. The native emission was measured at 430 nm after the excitation at 281 nm. A 0.5% Tween-80 solution was used to enhance fluorescence intensity. Peak amplitude of the first derivative synchronous was measured at 409 nm by using constant wavelength difference (Δλ = λem - λex = costant) which equal 160 nm. The regression plot of the proposed first derivative synchronous spectrofluorimetric method was found to be linear over the range of 50–300 ng/mL with a determination coefficient equals 0.9997, limit of detection (LOD) was 14.51 ng/mL but limit of quantification (LOQ) was 43.97 ng/mL.
Citer ce document
Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)
Accès au document
Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter
Voir l'article sur le site de la revueLicence et provenance
Licence : CC BY
Notice moissonnée depuis OpenAlex le 29/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →