Here, we investigate a gas sensor model based on phononic crystals of alternating tubes using the transfer matrix method to detect hazardous greenhouse gases. The effect of the thicknesses and cross-sections of all tubes on the performance of the proposed sensor is studied. The results show that longitudinal acoustic speed is a pivotal parameter rather than the mass density variations of the gas samples on the position of the resonant peaks due to its significant impact on the propagation of the acoustic wave. The suggested sensor can be considered very simple and low-cost because it does not need a complicated process to deposit multilayers of different mechanical properties' materials.

Citer ce document

Zaky, Z. A., Alamri, S., Zohny, E. I., & Aly, A. H. (2022). Simulation study of gas sensor using periodic phononic crystal tubes to detect hazardous greenhouse gases. Scientific Reports. https://doi.org/10.1038/s41598-022-26079-0