Accès ouvert · CC BY

Ex vivo and computational investigation of corneal iontophoresis to enhance penetration of high-molecular-weight compounds: a study using albumin as a model molecule

Article scientifique 2026 Sciences de la santé Anglais

Résumé

Efficient ocular drug delivery remains a major challenge due to the strong barrier properties of the corneal epithelium and the rapid clearance of topically applied formulations. This limitation is particularly critical for hydrophilic and high-molecular-weight (HMW) therapeutics such as proteins and biologics. In this study, we investigated transcorneal iontophoresis as a strategy to enhance the delivery of HMW compounds using albumin (66 kDa) as a model macromolecule. Ex vivo rabbit corneas were exposed to iontophoretic currents ranging from 0.5 to 7 mA for clinically relevant conditions, while an extreme non-clinical current (500 mA) was included as a destructive positive control to model irreversible tissue disruption. Albumin permeation was quantified by intrinsic fluorescence spectroscopy, and corneal structural responses were assessed using Fourier-transform infrared (FTIR) spectroscopy. In parallel, computational thermal modeling based on the Pennes bioheat equation was employed to evaluate current-dependent Joule heating and thermal safety margins. Results demonstrated that iontophoresis significantly enhanced albumin transport compared with passive diffusion, with increased permeation at higher currents, particularly at 6-7 mA. Thermal simulations indicated that currents ≤ 2 mA maintained corneal surface temperature within the normal physiological range (32-36 °C), while currents ≥ 3 mA progressively increased corneal temperature, approaching established thermal stress thresholds depending on exposure time. FTIR analysis revealed current-dependent spectral alterations consistent with changes in hydration dynamics, protein conformational environment, and lipid organization, suggesting reversible molecular adaptation at low-to-moderate currents and pronounced disruption at extreme electrical exposure. Collectively, this study identifies a practical current-time operational window for transcorneal iontophoresis that enhances macromolecular transport while maintaining corneal thermal and molecular integrity, supporting its potential for non-invasive ocular delivery of biologic therapeutics.

Citer ce document

Mohamed, A. K., Mahmoud, S. S., Elshibly, S. M., & Kamal, G. (2026). Ex vivo and computational investigation of corneal iontophoresis to enhance penetration of high-molecular-weight compounds: a study using albumin as a model molecule. Scientific Reports. https://doi.org/10.1038/s41598-026-43580-y

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 30/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 9

Téléchargements (hors robots) : 0

Méthode de comptage