{# Audit 04/10/2026 : « autre » n'est pas un code de langue ; SPHAERO n'est pas l'éditeur des documents qu'elle héberge ou référence. #} {# citation_pdf_url doit mener à un PDF : un lien vers une page DOI est pénalisé par Google Scholar (avant : tout lien externe). #}
Accès ouvert · CC BY

Reliability and validity of the World Health Organization reading standards for paediatric chest radiographs used in the field in an impact study of Pneumococcal Conjugate Vaccine in Kilifi, Kenya

Article scientifique 2018 Anglais

Résumé

BACKGROUND: Radiologically-confirmed pneumonia (RCP) is a specific end-point used in trials of Pneumococcal Conjugate Vaccine (PCV) to estimate vaccine efficacy. However, chest radiograph (CXR) interpretation varies within and between readers. We measured the repeatability and reliability of paediatric CXR interpretation using percent agreement and Cohen's Kappa and the validity of field readings against expert review in a study of the impact of PCV on pneumonia. METHODS: CXRs were obtained from 2716 children admitted between 2006 and 2014 to Kilifi County Hospital, Kilifi, Kenya, with clinically-defined severe or very-severe pneumonia. Five clinicians and radiologists attended a three-day training course on CXR interpretation using a WHO standard. All CXRs were read once by two local primary readers. Discordant readings and 13% of concordant readings were arbitrated by a panel of three expert radiologists. To assess repeatability, a 5% median random sample was presented twice. Sensitivity and specificity of the primary readers' interpretations was estimated against the 'gold-standard' of the arbitrators' results. RESULTS: Of 2716 CXRs, 2 were uninterpretable and 159 were evaluated twice. The percent agreement and Kappa for RCP were 89% and 0.68 and ranged between 84-97% and 0.19-0.68, respectively, for all pathological findings. Intra-observer repeatability was similar to inter-observer reliability. Sensitivities of the primary readers to detect RCP were 69% and 73%; specificities were 96% and 95%. CONCLUSION: Intra- and inter-observer agreements on interpretations of radiologically-confirmed pneumonia are fair to good. Reasonable sensitivity and high specificity make radiologically-confirmed pneumonia, determined in the field, a suitable measure of relative vaccine effectiveness.

Citer ce document

Ominde, M. S., Sande, J., Ooko, M., Bottomley, C., Benamore, R., Park, K., Ignas, J., Maitland, K., Bwanaali, T., Gleeson, F., & Scott, A. (2018). Reliability and validity of the World Health Organization reading standards for paediatric chest radiographs used in the field in an impact study of Pneumococcal Conjugate Vaccine in Kilifi, Kenya. PLoS ONE. https://doi.org/10.1371/journal.pone.0200715

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral en lecture en ligne, réservé aux abonnés SPHAERO et aux membres de l'institution. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 30/08/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations : 5

Téléchargements : 0