Accès ouvert · CC BY

Reliability and Feasibility of Visual Grading Systems and Quantitative Indexes on [99mTc]Tc-DPD Imaging for Cardiac Amyloidosis

Article scientifique 2022 Sciences de la vie et biotechnologies › Biotechnologies (OCDE 2.9) Anglais

Résumé

Abstract Background: We aimed to evaluate the reliability and feasibility of visual grading systems and various quantitative indexes of [99mTc]Tc-DPD imaging for cardiac amyloidosis (CA).Methods: Patients who underwent [99mTc]Tc-DPD imaging with suspicion of CA were enrolled. On the planar image, myocardial uptake was visually graded using Perugini’s and Dorbala’s methods (PS and DS). As [99mTc]Tc-DPD indexes, heart-to-whole body ratio (H/WB) and heart-to-contralateral lung ratio (H/CL) were measured on planar image. SUVmax, SUVmean, total myocardial uptake (TMU), and C-index were measured on SPECT/CT. Inter-observer agreement of the indexes and their association with visual grading and clinical factors were evaluated.Results: A total of 152 [99mTc]Tc-DPD images, of which 18 were positive, were analyzed. Inter-observer agreement was high for both DS (k = 0.95) and PS (k = 0.96). However, DS showed a higher correlation with quantitative indexes than PS. Inter-observer agreement was also high for SPECT/CT indexes, particularly SUVmax. SUVmax was significantly different between different DS groups (P = 0.014–0.036), and showed excellent correlations with H/WB and H/CL (r = 0.898 and 0.910). SUVmax also showed significant differences between normal, AL, and ATTR pathology (P = 0.022–0.037), and a significant correlation with extracellular volume on cardiac MRI (r = 0.772, P < 0.001).Conclusions: DS is a visual grading system for CA that is more significantly matched with quantitative indexes than PS. SUVmax is a reliable quantitative index on SPECT/CT, with a high inter-observer agreement, correlations with visual grade and cardiac MRI findings.

Citer ce document

Bae, S., Gil, J., Paeng, J. C., Park, E., Lee, S., Choi, H., Kang, K. W., Cheon, G. J., & Lee, D. S. (2022). Reliability and Feasibility of Visual Grading Systems and Quantitative Indexes on [99mTc]Tc-DPD Imaging for Cardiac Amyloidosis. Research Square. https://doi.org/10.21203/rs.3.rs-1337020/v1

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 06/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 11

Téléchargements (hors robots) : 0

Méthode de comptage