Accès ouvert · CC BY

The accuracy of extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella pneumoniae in South African laboratories using the Vitek 2 Gram-negative susceptibility card AST-N255

Article scientifique 2019 Sciences de la vie et biotechnologies › Biotechnologies (OCDE 2.9) Anglais

Résumé

Background: Phenotypic detection of extended-spectrum beta-lactamases (ESBLs) is based on the inhibition of ESBL enzymes by β-lactamase inhibitors and on the comparison of cephalosporin activity with or without a β-lactamase inhibitor. Many South African diagnostic laboratories rely on the Vitek 2 for automated susceptibility testing and for ESBL detection. However, the Gram-negative susceptibility card currently used locally (AST-N255) has been modified and its accuracy for ESBL detection is not known.Methods: We randomly selected 50 isolates of Klebsiella pneumoniae and Escherichia coli from a collection of clinical bloodstream isolates from Groote Schuur Hospital from 2015 to 2016, including ESBL-producing and non-ESBL-producing strains. We used standardised phenotypic (disc diffusion and broth microdilution) and genotypic (conventional polymerase chain reaction (PCR) for blaCTX-M, blaSHV and blaTEM) methods for detection of ESBLs. We compared ESBL detection by Vitek 2 to a composite reference standard comprising ESBL detection either by both phenotypic methods or by one phenotypic method together with genotypic detection.Results: The sensitivity of Vitek 2 system for detection of ESBLs was 33/36 or 92% (78% – 97%) for E. coli, and 40/40 or 100% (91% – 100%) for K. pneumoniae, whilst specificity was 10/10 or 100% (72% – 100%) and 9/10 or 90% (60% – 98%), respectively. This is comparable with previous studies.Conclusion: Using a composite reference standard of the phenotypic and genotypic methods employed in this study, no Vitek-categorised ESBL E. coli or K. pneumoniae was found to be a non-ESBL with the exception of possible misinterpretation with K. pneumoniae SHV-hyper-producing isolates.

Citer ce document

Young, A. L., Nicol, M. P., Moodley, C., & Bamford, C. (2019). The accuracy of extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella pneumoniae in South African laboratories using the Vitek 2 Gram-negative susceptibility card AST-N255. Southern African Journal of Infectious Diseases. https://doi.org/10.4102/sajid.v34i1.114

Exporter : BibTeX · RIS (Zotero, Mendeley, EndNote)

Accès au document

Texte intégral archivé sur SPHAERO, en accès ouvert : lisible gratuitement en ligne après connexion. Le document reste aussi disponible à sa source. Se connecter

Voir l'article sur le site de la revue

Licence et provenance

Licence : CC BY

Notice moissonnée depuis OpenAlex le 02/09/2026. Le document reste hébergé par sa source.
Voir le document à la source →

Statistiques

Consultations (hors robots) : 15

Téléchargements (hors robots) : 0

Méthode de comptage